MRC | Criteria | Characteristic |
---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 3 |
AHSX | FLANGE INSIDE WIDTH | 0.360 INCHES MINIMUM FIRST FLANGE AND 0.364 INCHES MAXIMUM FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 0.360 INCHES MINIMUM SECOND FLANGE AND 0.364 INCHES MAXIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.220 INCHES MINIMUM FIRST FLANGE AND 0.224 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.220 INCHES MINIMUM SECOND FLANGE AND 0.224 INCHES MAXIMUM SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 0.745 INCHES MINIMUM FIRST FLANGE AND 0.755 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 0.745 INCHES MINIMUM SECOND FLANGE AND 0.755 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 0.745 INCHES MINIMUM FIRST FLANGE AND 0.755 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 0.745 INCHES MINIMUM SECOND FLANGE AND 0.755 INCHES MAXIMUM SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.182 INCHES MINIMUM FIRST FLANGE AND 0.192 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.182 INCHES MINIMUM SECOND FLANGE AND 0.192 INCHES MAXIMUM SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.116 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.118 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.116 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.118 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.30 |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.358 INCHES MINIMUM AND 0.362 INCHES MAXIMUM |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.279 INCHES MINIMUM AND 0.282 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.139 INCHES MINIMUM AND 0.142 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.218 INCHES MINIMUM AND 0.222 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | COVER TYPE FIRST FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
FEAT | SPECIAL FEATURES | TWO LOADS INCLUDED |
FLEX | FLEXIBILITY | RIGID ALL TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY FIRST TUBING SEGMENT AND FLANGE |
MATT | MATERIAL | ALUMINUM ALLOY SECOND TUBING SEGMENT AND FLANGE |
SFTT | SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |