Buy 102-205-101 Part of Wood Electric Operations Potter And | NSN 5925-00-877-6757
-
Part Number: 102-205-101
-
Alternate P/N: 102205101
-
Manufacturer: Wood Electric Operations Potter And
-
NSN: 5925-00-877-6757 (5925008776757)
-
NIIN: 008776757
-
Item Name : Circuit Breaker
-
CAGE Code: 79405
-
FSG: 59 Electrical and Electronic Equipment Components
-
Country: USA
-
NCB Code: 00
-
Last Updated: 05-21-2025
-
Qty Available: 2634
Thank You for Choosing Buy Aviation Parts. We're pleased to inform you that 102-205-101 Part with NSN 5925008776757 is now available. Other details of 102-205-101 are as Circuit Breaker, manufactured by Wood Electric Operations Potter And. Fill out the RFQ Form for 102-205-101Part and Get Affordable Deal with Quick Delivery.
Characteristics Data of NSN 5925-00-877-6757, 5925008776757
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | VIBRATIONPROOF |
AAQL | Body Style | SINGLE POLE TYPE |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.812 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC AND |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
ABXD | Bushing Length | 0.156 INCHES NOMINAL |
FREQ | Frequency In Hertz | 400.0 SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC AND |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 32.0 DC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 3000.0 DC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 3000.0 AC AND |
CRCF | Trip Release Ambient Temp Rating | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
AKPX | Pole Quantity | 1 |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
ADAT | Body Width | 0.750 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 138.0 SINGLE LOCATION |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
CPRX | Actuator Position Designation | AT POLE ONE |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.000 INCHES NOMINAL |
ADAQ | Body Length | 2.189 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.188 INCHES NOMINAL |
THSD | Thread Series Designator | UNC |
TTQY | Terminal Type And Quantity | 2 SCREW |
MRC | Decoded Requirement | Clear Text Reply |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES DC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 70.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 18.000 MINIMUM AT 200 PCT AND |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CMLP | Thread Quantity Per Inch | 32 |
CQXF | Inclosure Protection Type For Which Designed | SALT SPRAY PROOF AND |
Upload RFQ Sheet