CAGE Code: 81541
-
FSG: 59 Electrical and Electronic Equipment Components
-
Country: USA
-
NCB Code: 01
-
INC Code: 00136
-
Last Updated: 05-23-2025
-
Qty Available: 2355
Thank You for Choosing Buy Aviation Parts. We're pleased to inform you that IUG66-1-62-20.0-Q-21 Part with NSN 5925014554106 is now available. Other details of IUG66-1-62-20.0-Q-21 are as Circuit Breaker, manufactured by Sensata Technologies Inc. Fill out the RFQ Form for IUG66-1-62-20.0-Q-21Part and Get Affordable Deal with Quick Delivery.
NSN Information for Part Number IUG66-1-62-20.0-Q-21 with NSN 5925-01-455-4106, 5925014554106
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-455-4106 Item Description: Circuit Breaker | 5925 | 014554106 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Iug66-1-62-20.0-Q-21 | 5 | 2 | 3 |
Characteristics Data of NSN 5925-01-455-4106, 5925014554106
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 4 WIRE LEAD |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRP | Ultimate Trip Time Per Pole In Seconds | 10.000 MINIMUM ALL LOCATIONS AND 120.000 MAXIMUM ALL LOCATIONS |
AJEC | Boss Height | 0.130 INCHES NOMINAL |
CPRT | Manual Actuator Type And Quantity | 2 TOGGLE |
ADAT | Body Width | 1.515 INCHES MAXIMUM |
ADTV | Case Material | PLASTIC |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADAQ | Body Length | 2.000 INCHES NOMINAL |
FEAT | Special Features | HANDLE IS RED WITH WHITE MARKINGS |
ADAU | Body Height | 1.640 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
THSD | Thread Series Designator | UNC |