Buy 232705023 Part of Northern Telecom Systems Corp | NSN 5905-00-513-1106
-
Part Number: 232705023
-
Manufacturer: Northern Telecom Systems Corp
-
NSN: 5905-00-513-1106 (5905005131106)
-
NIIN: 005131106
-
Item Name : Resistor Variable Nonwire Wound
-
CAGE Code: 06819
-
FSC: 5905 Resistors
-
FSG: 59 Electrical and Electronic Equipment Components
-
Country: USA
-
NCB Code: 00
-
INC Code: 37405
-
Last Updated: 05-22-2025
-
Qty Available: 2989
Thank You for Choosing Buy Aviation Parts. We're pleased to inform you that 232705023 Part with NSN 5905005131106 is now available. Other details of 232705023 are as Resistor Variable Nonwire Wound, manufactured by Northern Telecom Systems Corp. Fill out the RFQ Form for 232705023Part and Get Affordable Deal with Quick Delivery.
NSN Information for Part Number 232705023 with NSN 5905-00-513-1106, 5905005131106
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-513-1106 Item Description: Resistor Variable Nonwire Wound | 5905 | 005131106 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
232705023 | 1 | 9 | 5 |
Characteristics Data of NSN 5905-00-513-1106, 5905005131106
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.188 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.375 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.188 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.375 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 240.0 NOMINAL |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
APXH | TERMINAL LOCATION | REAR END |
AXGY | MOUNTING METHOD | TERMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 5.0 KILOHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
Upload RFQ Sheet