Buy A70-3678-45-257 Part of Drs Power And Control Technologies | NSN 5925-00-138-7585
-
Part Number: A70-3678-45-257
-
Alternate P/N: A70367845257
-
Manufacturer: Drs Power And Control Technologies
-
NSN: 5925-00-138-7585 (5925001387585)
-
NIIN: 001387585
-
Item Name : Circuit Breaker
-
CAGE Code: 27192
-
FSG: 59 Electrical and Electronic Equipment Components
-
Country: USA
-
NCB Code: 00
-
INC Code: 00136
-
Last Updated: 05-24-2025
-
Qty Available: 1506
Thank You for Choosing Buy Aviation Parts. We're pleased to inform you that A70-3678-45-257 Part with NSN 5925001387585 is now available. Other details of A70-3678-45-257 are as Circuit Breaker, manufactured by Drs Power And Control Technologies. Fill out the RFQ Form for A70-3678-45-257Part and Get Affordable Deal with Quick Delivery.
Characteristics Data of NSN 5925-00-138-7585, 5925001387585
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
ABHP | OVERALL LENGTH | 24.625 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 7.375 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 15.500 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.344 INCHES NOMINAL |
AKPX | POLE QUANTITY | 3 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | III SPECIAL HANDLING FEATURE | MAGNETIC |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 400.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 25000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
Upload RFQ Sheet